DASCOM Americas 2610 Manuel de l'opérateur Page 104

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 129
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 103
Tally Dascom 2610
91
7.2.8 LC printing
Certain professional applications may require unusually Large character sizes. Therefore your
printer has the possibility of scaling standard size characters up to factor 99 by means of
control sequences (LCP*).
The Header sequence defines the parameters (e.g. height) once. This definition remains
until the printer is switched off. The printable LCP* information is transmitted in an LCP
“bracket” (SI).
The following character sets (with national characters) are available.
ID
23
24
40
5B
5C
5D
5E
60
7B
7C
7D
7E
US ASCII
01
#
$
@
[
\
]
?
`
{
|
}
¯
GERMAN
02
#
$
§
Ä
*
Ü
?
`
ä
*
ü
ß
The character sets are selected via the following LCP sequence ESC ”P“ ”L“ ”S“ n ESC ”\“. The
value of n may range between 01 and 02 (as ASCII characters) – see ID column in the above
table.
To select e.g. the German character set, you must use the following data set:
ASCII
ESC
P
L
S
0
1
ESC
\
HEX
1B
50
4C
53
30
31
1B
5C
DEC
27
80
76
83
48
49*
27
92
The printout of LCP characters can be selected in all of the emulations.
Prerequisite: Printer must be in Barcode mode.
Note that this printer supports some scalable fonts in the LQ-2170 emulation if a
compatible driver is used.